Everything inside
stays breathing.
We'll show you what's between your servers and catastrophe.
Walk the Facility
Room 01 — Detection
The sensors that see smoke
before you smell it.
VESDA Aspirating
Detects smoke at 1/100th the density visible to the eye.
Air Sampling · Spec Sheet
VESDA Aspirating
- Xtralis VESDA-E VEA
- Response threshold: 0.005% obs/m
- Up to 40 sampling points per unit
- NFPA 72 / EN 54-20 listed
- Installed in 280+ raised-floor halls
Linear Heat Detection
Continuous sensing along every cable tray and conduit run.
Linear Heat · Spec Sheet
Linear Heat Detection
- Protectowire digital LHD
- Operating range: -40°C to +85°C
- Alarm accuracy: ±1°C
- UL Listed, FM Approved
- Ideal for sub-floor & overhead trays
Cross-Zoned Smoke
Two-detector voting prevents false discharges in live production.
Cross-Zone Smoke · Spec Sheet
Cross-Zoned Smoke
- Dual-path ionization + photoelectric
- Cross-zone logic: prevents nuisance discharge
- FACP integration: EST, Notifier, Simplex
- UL 268 listed
- 0 false discharges in 3 yr fleet avg
Room 02 — Suppression
The agent that kills fire
without touching the hardware.
Novec 1230
Zero ozone depletion. Discharged in 10 seconds. Equipment keeps running.
Fluoroketone Agent · Spec Sheet
Novec 1230
- 3M Novec 1230 fluid
- GWP: 1 (vs. CO₂ at 1)
- Design conc: 4.2% by vol
- Safe for occupied spaces
- ISO 14520 / NFPA 2001 compliant
- Installed: 340+ suppression zones
FM-200
Proven in 100,000+ installations. Fast-acting, leaves no residue.
HFC-227ea Agent · Spec Sheet
FM-200
- Chemours FM-200 (HFC-227ea)
- Design conc: 6.25–9% by vol
- Discharge time: ≤10 sec
- UL listed, FM approved
- NFPA 2001 / EPA SNAP approved
- Installed: 500+ suppression zones
IG-541 Inergen
Natural atmospheric gases. Permanent protection with no agent replacement.
Inert Gas Blend · Spec Sheet
IG-541 Inergen
- 52% N₂, 40% Ar, 8% CO₂
- Design conc: 37.5% by vol
- No environmental impact (GWP: 0)
- Discharge: 60 sec (high-pressure)
- NFPA 2001 / ISO 14520-15
- No recharge cost after false alarm
1,200+
Suppression Zones Protected
0
False Discharge Events (5yr)
4.2 hr
Average Mobilization Time
6
Agent Types Certified
Protected Zones by Year
Fleet growth, unbroken.
Compliance & Certification
Every mark that matters to your AHJ.
Every Suppress installation is documented, inspected, and delivered with a full compliance package — ready for your AHJ, insurance underwriter, or enterprise audit.
Room 03 — Integration
Wired into every system
you already run.
Suppress doesn't operate in a silo. Every suppression zone ties back to your operators, your dashboards, and your compliance record.
BMS Tie-In
Building Management Systems
Direct integration with Johnson Controls Metasys, Siemens Desigo, and Schneider EcoStruxure. Fire events surface in your existing operator console — no second screen.
DCIM Dashboard
Data Center Infrastructure Mgmt
API hooks into Nlyte, Vertiv Trellis, and Sunbird dcTrack. Zone-level suppression status maps directly onto your cabinet floor plan — live.
Remote Monitoring
24/7 Suppress Operations
Our NOC watches every panel, every zone, every hour. Alarm confirmation in under 90 seconds. Escalation to your on-call within 3 minutes of a real event.
Panel Compatibility
Fire Alarm Control Panels
Certified with EST3, Notifier NFS2-3030, and Simplex 4100ES. We write the cause-and-effect matrix; your team keeps the keys.
Annual Lifecycle
Inspection & Recharge
NFPA 2001 requires annual inspection. We schedule it, document it, and deliver the report your insurer needs — before they ask.
Legacy Replacement
Halon Retirement
Still running Halon 1301? We handle the full decommission — EPA-compliant reclaim, cylinder disposal, and clean-agent retrofit in a single coordinated shutdown.
Installed. Commissioned. Trusted.
From the people who
can't afford a second chance.



We had a Halon system from 1998 protecting $14M in storage. Suppress handled the retirement, the retrofit, and the AHJ inspection in a single scheduled window. Zero downtime. The documentation package alone was worth the contract.

Marcus Webb
VP of Facilities · CoreSite Data Centers
I spec'd Novec 1230 across six new halls in our Phoenix campus. Suppress had the design drawings in two weeks and the first zone commissioned before our hardware delivery. That's the pace hyperscale construction demands.

Priya Nair
Senior Construction PM · Switch Inc.
One sprinkler head in my raised floor would end careers. Suppress's cross-zoned detection and the 24/7 NOC monitoring means I actually sleep on Sunday nights. That's not marketing copy — that's the reality.

David Kowalski
Director of IT Infrastructure · Heartland Financial Group
Close the Door
Transparent pricing.
No surprises after the fire.
Detection Only
Complete air-sampling and smoke detection suite. No suppression agent. Ideal for facilities already holding FM-200 cylinders.
- VESDA aspirating system
- Cross-zoned smoke detectors
- FACP integration (EST, Notifier, Simplex)
- Commissioning + AHJ sign-off
- As-built documentation package
Detection + Suppression
Full detection loop plus clean-agent suppression. Choose Novec 1230, FM-200, or inert gas blend. The most common spec for new builds.
- Everything in Detection Only
- Clean-agent cylinder & piping
- Novec 1230 / FM-200 / IG-541 (your choice)
- Abort switch + pre-discharge alarm
- BMS / DCIM integration
- 1-year post-install inspection included
Full Lifecycle
Detection, suppression, 24/7 monitoring, annual inspection, and Halon retirement if applicable. One contractor, zero gaps.
- Everything in Detection + Suppression
- 24/7 Suppress NOC monitoring
- Annual NFPA 2001 inspection
- Insurance-ready compliance reports
- Halon decommission (if applicable)
- Dedicated account engineer
Not ready to spec? Some facilities need a trained eye first.
No commitment. We walk the floor, identify gaps, and leave you a written assessment.